HAWK SAFETY TOOL FOR BLOWOUT PREVENTERS

Testing

We have gradually proven the method in size, flow rate, and pressure. The last tests completed demonstrated the feasibility of creating an entanglement in an 11" wellbore with and without a drill pipe. We also demonstrated the ability of the tangled continuous structure to clog an open aperture of 3" diameter in that wellbore and hold a back pressure of at least 10,000 psi. Currently updating this section of the website. Photos coming soon.

Test Summary: Wellbore diameter vs parameters

Test 1 inch 4 inch 6 inch 11 inch
Low Pressure < 500 psi
Yes
Yes
Yes
Low Flowrate
Yes
Yes
Yes
Mid Pressure ~ 2k psi
Yes
Yes
Mid Flowrate
Yes
Yes
High Pressure <~11k psi
Yes
High Flowrate
Yes

Pre- High Pressure Overview


Tool Layout & Preliminary Benchtop testing

HAWK Safety Tool Layout

Diagram of HAWK tool showing spools feeder head and housing

Bench Top Testing

Experiment benchtop showing wire feeder into a clear chamber with a pipe down the center.